HSQIHealthcare Safety and Quality Institute

How to write a nonconformity and a corrective action that closes it

Healthcare Safety and Quality Institute, 28 November 2026. 3 min read.

Most internal audit reports fail at the same point. The auditor saw a real problem, but wrote it so loosely that the department could close it with a signature. This article shows how to write a finding that leads to a real fix. It applies equally to hospitals working to NABH or JCI and to laboratories working to ISO 15189.

The three parts of a nonconformity

  1. The requirement. Which clause, objective element or internal procedure was not met.
  2. The finding. What was observed, stated as a fact.
  3. The evidence. The record, place, date or sample that shows it, so that anyone can verify it.

A weak finding

"Crash cart checking is not proper."

The same finding, written well

"The hospital procedure requires the emergency trolley to be checked daily and after each use. In Ward 3, the checklist for the current month had no entries on six dates, and one ampoule in the trolley had passed its expiry date. The checklist and the trolley were seen with the nurse in charge."

The second version tells the department exactly what to fix and tells the next auditor exactly what to check.

Rules for writing

  • State facts. Leave out opinions and words such as "poor", "improper" and "careless".
  • Do not name or blame a person. Refer to the role and the record.
  • One nonconformity per finding. Do not bundle three problems into one.
  • Agree the facts with the department before you leave the area.

Correction is not corrective action

  • Correction fixes the thing found. The expired ampoule is replaced today.
  • Corrective action removes the cause so that it does not happen again.

A report that stops at correction will meet the same finding at the next audit.

Finding the root cause

Ask "why" until you reach something in the system that can be changed. The ampoule expired. Why? Nobody checked expiry dates. Why? The daily checklist covers presence of items, not expiry. Why? The checklist was copied from an old format. The corrective action is now clear: revise the checklist to include a monthly expiry check and train the staff who use it. "Staff counselled" is rarely a root cause; it usually means the analysis stopped too early.

Check that it worked

Closing a finding needs evidence that the action was taken and that it was effective. Set a date, some weeks later, to look again. If the trolley checklists in that ward and in two other wards are complete and no expired items are found, the action worked. Record that check. Only then is the nonconformity closed.

Look sideways

If the problem was found in one ward, ask whether it exists in the others. Extending the fix to similar areas is what turns an audit finding into an improvement.

Learn the full method

Audit planning, interviewing, writing findings and managing corrective action are taught in the Healthcare Quality Professional Certificate Course (HQPC) for hospitals and in the ISO 15189 Internal Auditor Course for laboratories. Both include a ready-to-use nonconformity report format.

More articles